FTIR Multi Componenten Analyse Systeem MCS100FT

FTIR Multi Componenten Analyse Systeem MCS100FT

MCS100FT – FTIR Multi-Component System for Monitoring of Gaseous Emissions

Everything under control with advanced, proven technology

The FTIR measuring principle allows the simultaneous determination of more than 12 measuring components – tailor-made for the particular requirements of the customer. The MCS100FT FTIR analyzer system with its heated measuring cell enables the monitoring of hydrogen fluoride limits as requested by legislation. The MCS100FT is equipped with an oxygen sensor as standard and can be supplemented with a total hydrocarbon analyzer. With its reliable measuring technology, its easy operation and low maintenance requirements, the MCS100FT provides a solution that offers unequalled opportunities.

The robust CubeCorner interferometer in combination with the newly developed measuring cell and the chemometrical evaluation procedure provide very reliable and stable measuring results.

Specifications

Measuring principle
FTIR
Ambient temperatures
+5 °C ... +35 °C
With cooling device: +5 °C ... +50 °C
Interfaces
RS-232 / RS-422 / RS-485 / Ethernet
Bus protocol
Modbus RTU / OPC / SOPAS ET / PROFIBUS DP (option)
Protection class
IP43; Optional IP54
Conform
2001/80/EC, 2000/76/EC,
27.BImSchV, TA-Luft, EN 15267,
EN 14181, MCERTS
Analogue outputs
0/4 ... 22mA, max. load 500Ω
Number depends on system configuration, electrically isolated, max. 32 outputs
Analogue inputs
0/4 ... 22mA, max. load 500Ω
Number depends on system configuration, electrically isolated, max. 32 inputs
Digital outputs
3.9V, 4.5 mA, 0.55 W
Number depends on system configuration, max. 64 inputs
Digital inputs
3.9V, 4.5 mA, 0.55 W
Number depends on system configuration, max. 64 inputs
Detection limit
< 2 % of measuring range full scale
EN14181 QAL1 certificate
Yes
EN 15267-3 certificaat
Yes
Response time
≤ 200 s; FID: ≤ 45 s
Measuring gas temperature
≤ +1300 °C
Dimensions (H x W x D)
2165 x 806 x 605mm
Display
LC-display
Status-LED's: *Power*, *Maintenance* and *Failure*
Weight
≤ 260 kg
Electrical safety
CE
Max flow
≤ 300 l/h

Features:

  • Lowest approved HF measuring range: 0 … 3 mg/m³
  • Automatic spectrum adjustment via AutoVAL for reliable measuring values
  • Operation via touchscreen
  • Sample gas transport by an ejector without moving parts
  • Approved according to EN 15267
  • Remote control and diagnosis via software SOPAS ET
  • Automatic adjustment of analyzer
  • Automatic backflushing and filter cleaning of sampling unit

Benefits:

  • Genuine HF threshold value monitoring
  • Only one analyzer for more than 12 measuring components
  • Easy integration into the customer network environment
  • Long maintenance interval of 6 months for many components
  • Type approved measurement of greenhouse gases such as N2O, CH4, and CO2
  • Low maintenance requirements save time

Applications:

  • Emission monitoring in waste incineration plants
  • Effective HF limit value monitoring, e. g., in aluminum production
  • Monitoring of gaseous emissions in cement plants or power stations